The identification of the database changed

Hello,

since last friday, the identification number of our database was :

49eec8ce7f156cde

since monday it is :

5326a4a459d805c7

Who is it possible ????!!!!

Of course, now all the DXL using references of module does not work any more.  :-(

Database version : DOORS 9.5

Pierre

 


PDU - Tue Mar 18 04:09:18 EDT 2014

Re: The identification of the database changed
Pekka_Makinen - Tue Mar 18 08:23:39 EDT 2014

Database ID change should not be possible, but seems to happen - see this older discussion on the same issue https://www.ibm.com/developerworks/community/forums/html/topic?id=77777777-0000-0000-0000-000014246669

Re: The identification of the database changed
PDU - Wed Mar 19 09:31:44 EDT 2014

Pekka_Makinen - Tue Mar 18 08:23:39 EDT 2014

Database ID change should not be possible, but seems to happen - see this older discussion on the same issue https://www.ibm.com/developerworks/community/forums/html/topic?id=77777777-0000-0000-0000-000014246669

Very interesting,

it is impossible, but sometime ...

So an other question :

is it possible in all DXL attributes in all modules in all projects replace old Database Id by new ?


(i write a similar question in DXL forum)

Re: The identification of the database changed
llandale - Thu Mar 20 13:02:58 EDT 2014

Don't know.  Check the versions of all the Clients, the exact versions, and check the DB properties for "minimum" and "maximum" allowed client versions.  Include check of the Client version on the Server as well as the Server version on the Server.

Incidentally, I'm confident that you need only replace that "config.dtc" file in the db root folder, not restore the entire database.

-Louie

Re: The identification of the database changed
PDU - Fri Mar 21 01:46:39 EDT 2014

llandale - Thu Mar 20 13:02:58 EDT 2014

Don't know.  Check the versions of all the Clients, the exact versions, and check the DB properties for "minimum" and "maximum" allowed client versions.  Include check of the Client version on the Server as well as the Server version on the Server.

Incidentally, I'm confident that you need only replace that "config.dtc" file in the db root folder, not restore the entire database.

-Louie

Hi Louie,

all clients are in version 9.1.0.2, server in 9.5.1.0.95095.

DB properties for "minimum" and "maximum" are empty.

Thanks very much for the solution with "config.dtc" file, works fine.  :-)